Parallel constant wattage heating cables can be used for pipe and equipment freeze protection and process temperature maintenance where high power output or high temperature exposure is required. This type offers an economical alternative to self-regulating heating cables, but requires more installation skill and a more advanced control and monitoring system.Constant wattage heating cables can provide process temperature maintenance up to 150°C and can Withstands exposure temperatures up to 205°C when powered on.
1. Product introduction of Parallel constant power
Parallel constant power heating cables can be used for pipeline and equipment antifreeze protection and process temperature maintenance that requires high power output or high temperature exposure. This type of self-regulating heating cable provides an economical alternative, but it needs more installation skills and more advanced control and monitoring. The constant wattage heating cable can maintain the process temperature as high as 150℃ and can withstand the exposure temperature as high as 205℃ when the power supply is connected.
2. Product specifications and models of Parallel constant power
Parallel constant power
3. Structure of Parallel constant power
HGW single-phase constant power heating cable is used for antifreeze and thermal insulation of various pipelines and instruments. Factory area 1, area 2 explosive gas atmosphere area and other applications.
1). Tinned copper stranded wire
2). FEP insulation layer
3). FEP insulation layer
4). Ni-Cr alloy wire
5). FEP insulation layer
6). Tinned copper braided layer
7). FEP outer sheath
4. Working criterion of Parallel constant power
Two parallel twisted copper wires are used as bus bars with insulation layer FEP, and then the Ni-Cr alloy is used as a hot wire to be wound with bus lines regularly, starting with parallel resistors, and finally covered with insulation sheath FEP. When the bus power supply is turned on, each parallel resistor begins to heat, thus forming a continuous heating cable.
5. Product specifications and technical features of Parallel constant power
part number |
Rated power (W/m) |
Maximum service length (m) |
Maximum maintenance temperature (℃) |
Sheath color |
|
Common models |
Reinforced model |
||||
HGWF-10/2P |
HGWF-10/2J |
10 |
210 |
150℃ |
red |
HGWF-20/2P |
HGWF-20/2J |
20 |
180 |
120℃ |
red |
HGWF-30/2P |
HGWF-30/2J |
30 |
150 |
90℃ |
red |
HGWF-40/2P |
HGWF-40/2J |
40 |
140 |
red |
red |
Rated voltage: 220V/380V/660V.
Maximum exposure temperature: 205℃
Normal insulation resistance: ≥20M ohms
Protection grade: IP54
Dielectric strength: 2000V 50Hz/1min
Size: 6.3x9.5mm
Insulation material: FEP
Ratification: CE EX
6. Three-phase constant power heating cable
Three-phase constant power heating cable can use three-phase triangle power supply, which has the characteristics of single-phase constant power heating cable. It is especially suitable for heat tracing and preservation of long-distance and large-diameter pipelines. T3 area of explosive gas and other application mixtures in Zone 1 and Zone 2 of the factory.
1). Tinned copper stranded wire
2). FEP insulation layer
3). FEP insulation layer
4). Ni-Cr alloy wire
5). FEP insulation layer
6). Tinned copper braided layer
7). FEP outer sheath
7. Working criterion of Parallel constant power
Three parallel twisted copper wires are used as bus bars with insulation layer FEP, and then the Ni-Cr alloy is used as heating wire to be wound with the bus bars at regular intervals, and the resistance between the two parallel phases is repeatedly connected circularly (for example, AB-BC-CA-AB), and finally covered with insulation sheath FEP. When the bus power supply is connected to three phases, each parallel resistor starts to generate heat, thus forming a continuous heating cable.
8. Product specifications and technical features
part number |
Rated power (W/m) |
Maximum service length (m) |
Maximum maintenance temperature (℃) |
|
|
Common models |
Reinforced model |
||||
HGWF-10/2P |
HGWF-10/2J |
10 |
210 |
150℃ |
red |
HGWF-20/2P |
HGWF-20/2J |
20 |
180 |
120℃ |
red |
HGWF-30/2P |
HGWF-30/2J |
30 |
150 |
90℃ |
red |
HGWF-40/2P |
HGWF-40/2J |
40 |
140 |
65℃ |
red |
Rated voltage: 380V/660V/1100V v.
Maximum exposure temperature: 205℃
Normal insulation resistance: ≥20M ohms
Protection grade: IP54
Dielectric strength: 2500V 50Hz/1min
Size: 6.3x12mm
Insulation material: FEP
Ratification: CE EX