Products
Products
MI cable product model

MI heating cable

Cover material: (316L) stainless steel, (CU) copper, (AL) 825 alloy, (CN) copper-nickel alloy

MI heating cable

1. Product introduction of MI cable product model

Note: Structure of cable components: A, B, D, E, H, J;

Number of wire cores: 1,2;

Cover material: (316L) stainless steel, (CU) copper, (AL) 825 alloy, (CN) copper-nickel alloy

 

2. Cable element structure:

Heating cable model code:

1 6 A 65600

figure

1 2 3 4

Number number

description

1

Number of core lines

1= single core, and 2= double core

2

Maximum rated voltage

3=300V,4=400V,6=600V

3

The wire material

A,B,C,D,E,F,G,H

4

Cold-state resistance, x10000

65,600 = 6.56 (Ω / m) x10000 at 20℃

 

3. Technical parameter:

model

specifications

(mm²)

specifications

(mm)

insulation thickness

(mm)

External diameter of finished product

(mm)

Single root longest length

(m)

withstand voltage

(V)

end-use temperature

(℃)

maximum current

(A)

MI-AL

MI-316L

MI-CN

MI-CU

0.4

0.39

0.65

3.0

300-350

1500

250-800

23

0.7

0.38

0.70

3.2

280-320

1500

250-800

32

1.0

0.385

0.75

3.5

250-320

1500

250-800

41

1.5

0.420

0.85

4.0

200-250

1500

250-800

50

2.5

0.460

0.90

5.0

100-200

1500

250-800

67

4.0

0.50

1.00

6.0

100-150

1500

250-800

75

6.0

0.85

1.50

8.0

50-80

1500

250-800

90

8.0

1.10

2.00

10.0

30-50

1500

250-800

100

10.0

1.25

2.30

12.0

20-30

1500

250-800

120

Note: Special specifications can be customized, for the specific design selection, please contact our technical personnel.

 

4. Natural Parameter:

parameter

Copper core copper sleeve structure

Kang copper core copper sleeve structure

Nickel-chromium-core stainless steel sleeve structure

Rated power (W / m)

5-30

20-100

50-295

Maximum surface temperature of (℃)

200

400

800

Maximum operating temperature is (℃)

150

350

650

external diameter (mm)

Single core

3-6

3.5-6

3.5-6.5

twin-core

6-10

6-11

5.5-11

Cover material

Conductor cell line

oxygen-free copper

Kang copper, PTC alloy

nichrome

insulation material

magnesia powder

magnesia powder

magnesia powder

metallic sheath

fine copper

colomony

stainless steel

MI heating cable

Send Inquiry
For inquiries about our products or pricelist, please leave your email to us and we will be in touch within 24 hours.
Related Products
TXLP dual hair heating line

TXLP/2R 220V dual-guide heating cable is mainly used in floor heating, soil heating, snow melting, pipeline heating, etc.

Read More
TXLP single -direction heat line

<p>There is no need to lay a cement layer, and it can be directly buried under the 8-10mm adhesive of the ground decoration material. Flexible laying, easy installation, easy standardization and operation, suitable for various floor decoration materials. Whether it is a concrete floor, wooden floor, old tile floor or terrazzo floor, it can be installed on the tile glue with little effect on the ground level.</p>

Read More
Ground heating cable carbon fiber heating wire electric hotline new infrared heating pad

TXLP/1 220V single-guide heating cable is mainly used in floor heating, soil heating, snow melting, etc.

Read More
Parallel constant power

<p>Parallel constant wattage heating cables can be used for pipe and equipment freeze protection and process temperature maintenance where high power output or high temperature exposure is required. This type offers an economical alternative to self-regulating heating cables, but requires more installation skill and a more advanced control and monitoring system.Constant wattage heating cables can provide process temperature maintenance up to 150&deg;C and can Withstands exposure temperatures up to 205&deg;C when powered on.</p>

Read More
Self-limiting heating cable-GBR-50-220-FP

<p>High temperature shielded type, the output power per meter is 50W at 10&deg;C, and the working voltage is 220V.</p>

Read More
Selflimiting heating cable-ZBR-40-220-J

<p>Medium temperature shielded type, the output power per meter is 40W at 10&deg;C, and the working voltage is 220V.</p>

Read More
Series constant power heating cable

<p>HGC series connecting constant power heating cables use core conductor as heating element.</p>

Read More
Silicone strap

<p>Silicone sheet electric heating belt is a thin strip heating product (standard thickness is 1.5mm). It has good flexibility and can be wrapped around a pipe or other heating body with heat-resistant tape to fix it like a rope, or it can be directly wrapped in a heated The outside of the body is fixed with a spring hook, and the heating performance is better if an insulation layer is added. The heating element is made of nickel-chromium wire wrapped with heat-conducting and insulating silicone material, which is molded at high temperature, so the safety performance is very reliable. Pay attention to avoid overlapping winding installation as much as possible, so as not to affect heat transfer and affect the service life of the product.</p>

Read More
Top

Home

Products

whatsapp